Process Technology

Wet Process Heating and Cooling Equipment

NR Series, Non-indicating Thermostats

MODEL
NUMBER

VOLTS

MAX.
AMPS
TEMP.
RANGE
SENSOR
LENGTH Ft./(m)
REPL.
SENSOR P/N
SHIP WGT.
Lbs./(kg)
NR25 120/240 25* 30° to 220°F 5' (1.5m) NR25-5L 3 (1.5)
NR25-12 120/240 25 30° to 220°F 12' (3.7m) NR25-12L 3 (1.5)
N25H 120/240 25 200° to 550°F 5' (1.5m) N25H-5L 3 (1.5)

*For heating only.
**
Thermal Protection Systems

Product Features and Benefits:

IMPROVES PROCESS CONTROL: Large, easy to read dial. Provides general control and consistent plating and etch rates in most aqueous processes.

TEMPERATURE SENSOR: Fluoropolymer (FEP) covered 5-foot (1.5m) copper bulb and capillary provided standard with the control. Provides extended service in corrosive liquids. Ethylene glycol filled system.

CORROSION RESISTANT ENCLOSURE: Vapor tight, NEMA 1, IP23, flame retardant gasketed plastic enclosure with stainless steel hardware.

CAPACITIES:

Double pole, single throw switches rated at 25 amps for either 120 or 240 volts.
Adjustable temperature range from 30°F to 220°F.
+/- 5°F accuracy.
30°F (-1°C) to 150°F (65°C) ambient temperature range.
Single phase only.

SAFETY FEATURES:

Pre-wired P1 terminal blocks.
Ground connection on thermostat.

OPTIONS AVAILABLE (consult factory):

12-foot (3.6m) sensors.
Combination controls available for three phase service and larger heater loads.
Pre-wired outlets for plug-in heaters.
200°F to 550°F temperature range.

DOWNLOAD THE INFORMATION SHEET (including dimensional diagram)

[ Home | Search our Site | Industrial Products | Aquaculture Products ]
[
High Purity Products | Product Specials | Company Profile ]
[ Trade Shows | What's New | Employment Opportunities ]
[ Troubleshooting Guide | PDF Files | Contact Us ]

Copyright © 2012 Process Technology
info@process-technology.com